This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.
Ask the Experts: Have a Question on Managing VMware Workloads on Azure?
Tripp Lite 120V 1.5KVA 1.35kW Double-Conversion UPS, 2U R T, Ext. Run, WEBCARDLX, LCD, USB, DB9 (SU1500RTXLCDN)
Ordering Information
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
The SU1500RTXLCDN SmartOnline 120V 1.5kVA 1.35kW On-Line Double-Conversion UPS provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. It converts AC input to DC power, and then converts DC to fully regulated sine wave AC output with +/-2% voltage regulation in online and battery modes.
Featuring six NEMA 5-15R outlets in two switchable numbered load banks, as well as a NEMA 5-15P input, the SU1500RTXLCDN has an internal battery that provides 14 minutes of support at half load and 4.2 minutes at full load. Adding external battery packs, such as BP48V24-2U(sold separately), provides extended runtime.
The pre-installed WEBCARDLX network interface accessory card permits remote management, including reboots, configuration, updates and activity logs. An interactive front-panel LCD interface displays operating conditions and diagnostic data, such as load, voltage and battery levels. You can set operating modes to reflect your protection priorities, including an optional economy mode that saves heat output and energy costs.
EMI/RFI noise filtering improves your equipment's performance and prevents damage. A 570-joule surge suppression rating protects your equipment from harmful power surges. With Tripp Lite's included POWERALERT12 software, the SU1500RTXLCDN enables safe unattended system shutdown and file saves in case of a prolonged power failure. An audible alarm indicates startup/shutdown, power failure, low battery, overload and fault conditions.
Featuring six NEMA 5-15R outlets in two switchable numbered load banks, as well as a NEMA 5-15P input, the SU1500RTXLCDN has an internal battery that provides 14 minutes of support at half load and 4.2 minutes at full load. Adding external battery packs, such as BP48V24-2U(sold separately), provides extended runtime.
The pre-installed WEBCARDLX network interface accessory card permits remote management, including reboots, configuration, updates and activity logs. An interactive front-panel LCD interface displays operating conditions and diagnostic data, such as load, voltage and battery levels. You can set operating modes to reflect your protection priorities, including an optional economy mode that saves heat output and energy costs.
EMI/RFI noise filtering improves your equipment's performance and prevents damage. A 570-joule surge suppression rating protects your equipment from harmful power surges. With Tripp Lite's included POWERALERT12 software, the SU1500RTXLCDN enables safe unattended system shutdown and file saves in case of a prolonged power failure. An audible alarm indicates startup/shutdown, power failure, low battery, overload and fault conditions.
-
45.20 lbs
-
Features
Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
+/-2% voltage regulation in online and battery modes
Selectable 100/110/120/127V output voltage
(6) NEMA 5-15R outlets
10 ft. power cord with NEMA 5-15P input
570-joule surge suppression rating
Supports half load for 14 min. and full load for 4.2 min.
Zero transfer time suitable for advanced network applications
Expandable runtime with optional external battery packs, such as Tripp Lite's BP48V24-2U
Restarts automatically after lengthy power outages
Pre-installed WEBCARDLX network interface permits remote management of UPS, including reboots, configuration, updates and activity logs
Outlets are divided into 2 numbered load banks, each of which may be individually powered on and off remotely to reset or reboot connected equipment
Interactive LCD Screen rports detailed status information, including load, voltage and battery levels
Offers advanced configuration and setup options, including output voltage and operating mode
Removes electromagnetic and radio frequency interference that can disrupt or damage equipment's performance
Audible Alarm indicates startup/shutdown, power failure, low battery, overload and fault conditions
USB and DB9 ports combine with included POWERALERT12 software to monitor operating conditions, monitor AC power and enable safe unattended system shutdown and file saves in case of a prolonged power failure
EPO port supports emergency shutdown in large facilities
Hardware included for 4-post mounting in 2U of EIA-standard 19 in. rack
Mounts on wall or 2-post rack with optional 2POSTRMKITWM
Mounts in upright tower position with optional 2-9USTAND
USER INTERFACE, ALERTS & CONTROLS
Front Panel Display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
Switches: (2) switches control off/on power status and alarm-cancel operation; (2) additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
LED Indicators: (7) front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status -
# Ports: 6Communication Interface: EthernetCommunication Interface: Serial (RS-232)Communication Interface: USBConnector: Power NEMA 5-15 (F)Connector: Power NEMA 5-15 (M)Connector: Power NEMA 5-15P
-
UPS, WEBCARDLX network interface, USB cable, DB-9 cable, EPO cable, PowerAlert software, mounting hardware, documentation
-
Attributes: Double conversion onlineAttributes: RJ-11 line protectionAttributes: RJ-45 line protectionColor: BlackForm Factor: 2U RackmountForm Factor: Rack-mountableForm Factor: Rack-mountable / externalForm Factor: TowerWarranty Period: 2 yearsWeight Taxonomy: 42.55lbsWeight Taxonomy: 45.19lbs
-
3.5"h x 17.5"w x 18.5"d
-
Output Receptacles: (6) 5-15R
Load Management Receptacles: Two switchable three-outlet 5-15R load banks
UPS Input Connection Type: 5-15P
-
Battery Run Time (max): 4.2minBattery Run Time (max): 5.8minBattery Technology: Valve regulated lead-acid (VRLA)Power Capacity (VA): 1500VAPower Provided: 1350Power Provided: 1350WSurge Suppression: StandardSurge Suppression: YesVoltage Provided: 120VVoltage Provided: 48VVoltage Provided: DC 48V
-
OUTPUT
Output Capacity: 1500VA/1350W
Output Capacity Details: ON LINE MODE Maximum output capacity ratings is reduced to 1215 watts at 115V nominal and 1080 watts at 100V nominal; FREQUENCY REGULATION / CONVERSION MODE Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts / 115V 850 watts / 110V 804 watts / 100V 756 watts) OVERLOAD CAPACITY Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Power Factor: 0.9
Crest Factor: 3:1
Nominal Output Voltages Supported: 100V; 110V; 115V; 120V; 127V
Nominal Voltage Details: 120V factory-default nominal voltage; Less than 3% THD for linear loads and less than 5% for non-linear computer loads
Frequency Compatibility: 50/60 Hz; Supports 50 to 60Hz and 60 to 50Hz conversion
Frequency Compatibility Details: ON LINE MODE Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE Output is regulated to +/-0.05Hz.
Output Voltage Regulation (Line Mode): +/- 2%
Output Voltage Regulation (Economy Line Mode): +/- 10%
Output Voltage Regulation (Battery Mode): +/- 3%
Output AC Waveform (AC Mode): Pure Sine wave
Output AC Waveform (Battery Mode): Pure Sine wave
INPUT
Rated input current (Maximum Load): 12A
Nominal Input Voltages Supported: 100VAC; 110VAC; 115VAC; 120VAC; 127VAC
Nominal Input Voltage Description: 120V factory default
Input Circuit Breakers: 20A
UPS Input Cord Length: 10ft
Recommended Electrical Service: 15A 120V
Input Phase: Single-Phase
BATTERY
Full Load Runtime: 4.2 min. (1350w)
Half Load Runtime: 14 min. (675w)
Expandable Battery Runtime: Extended runtime supported via optional external battery packs
External Battery Pack Compatibility: BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible)
Expandable Runtime Description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
DC System Voltage: 48VDC
Battery Recharge Rate (Included Batteries): Less than 3 hours recharge to 90%; Add 6 hours per BP48V27-2US (typical, full load discharge)
Internal UPS Replacement Battery Cartridge: RBC94-2U
Battery Access: Front panel battery access
Battery Replacement Description: Hot-swappable, user replaceable batteries
Expandable Runtime: Yes
VOLTAGE REGULATION
Voltage Regulation Description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
Overvoltage Correction: Corrects overvoltages to 150V (0-100% load)
Undervoltage Correction: Corrects undervoltages to 100V at full load (90V at 100V nominal)
Severe Undervoltage Correction: Corrects brownouts to 70V (70% load) & 55V (33% load)
SURGE / NOISE SUPPRESSION
UPS AC Suppression: 570 Joules
UPS AC Suppression Response Time: Instantaneous
UPS Dataline Suppression: 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC Noise Suppression: Yes -