This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.
Al Is Here. Are You Ready? Explore Tips on Your Device Refresh Strategy
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
The CyberPower Smart App Online OL1000RTXL2U rack/tower uninterruptible power supply (UPS) with LCD control panel and pure sine wave output safeguards mission-critical servers, data center and telecom equipment, VoIP and internetworking hardware that require seamless power correction. Its Double-Conversion topology is generator compatible and delivers consistent and clean AC power with zero transfer time, protecting connected equipment and preventing costly business interruptions. Auto-bypass insures connected equipment continues to operate seamlessly when an overload or internal fault is detected.
Configurable GreenPower UPS ECO Mode improves UPS efficiency to 93% and reduces electrical and cooling costs. Smart Battery Management (SBM) uses a 3 cycle charging mode to improve battery life while reducing heat being generated.
The LCD control panel provides 43 different settings to check status and customize the operating parameters for the OL1000RTXL2U, plus it can be removed and mounted separately from the UPS for ease of use regardless of where the UPS is installed. Functions include menus for checking power status on (19) different parameters, (23) settings for setup, control and testing of the UPS and (1) selection for event logging. With a DB26 cable (sold separately) the LCD control panel can be removed from the UPS and relocated up to 10ft. away from the UPS for ease of viewing when installed in hard to reach locations.
The UPS incorporates microprocessor-based fully digital control and includes PowerPanel® Business Edition providing the user unsurpassed flexibility and control. An optional SNMP/HTTP Remote Management adapter (RMCARD302) supports remote management and control of the OL1000RTXL2U through a standard web browser.
The OL1000RTXL2U unit has a capacity of 1,000VA/900Watts (0.9 power factor) that can be configured for an output of 100V, 110V, 115V, 120V and 125V +/- 2%. It features eight (8) outlets with NEMA 5-15R receptacles and maintenance-free, hot swappable, user-replaceable batteries. This unit offers connectivity via one (1) HID USB, one (1) DB9 serial and one (1) emergency power off (EPO) port. Network grade surge suppression and EMI/RFI filters increase the immunity of the load to noise disturbances. The runtimes are expandable by adding a hot swappable, user replaceable BP36V60ART2U Extended Battery Module (EBM).
A Three-Year Warranty ensures that this UPS has passed our highest quality standards in design, assembly, material or workmanship and further protection is offered by a $400,000 Connected Equipment Guarantee.
Configurable GreenPower UPS ECO Mode improves UPS efficiency to 93% and reduces electrical and cooling costs. Smart Battery Management (SBM) uses a 3 cycle charging mode to improve battery life while reducing heat being generated.
The LCD control panel provides 43 different settings to check status and customize the operating parameters for the OL1000RTXL2U, plus it can be removed and mounted separately from the UPS for ease of use regardless of where the UPS is installed. Functions include menus for checking power status on (19) different parameters, (23) settings for setup, control and testing of the UPS and (1) selection for event logging. With a DB26 cable (sold separately) the LCD control panel can be removed from the UPS and relocated up to 10ft. away from the UPS for ease of viewing when installed in hard to reach locations.
The UPS incorporates microprocessor-based fully digital control and includes PowerPanel® Business Edition providing the user unsurpassed flexibility and control. An optional SNMP/HTTP Remote Management adapter (RMCARD302) supports remote management and control of the OL1000RTXL2U through a standard web browser.
The OL1000RTXL2U unit has a capacity of 1,000VA/900Watts (0.9 power factor) that can be configured for an output of 100V, 110V, 115V, 120V and 125V +/- 2%. It features eight (8) outlets with NEMA 5-15R receptacles and maintenance-free, hot swappable, user-replaceable batteries. This unit offers connectivity via one (1) HID USB, one (1) DB9 serial and one (1) emergency power off (EPO) port. Network grade surge suppression and EMI/RFI filters increase the immunity of the load to noise disturbances. The runtimes are expandable by adding a hot swappable, user replaceable BP36V60ART2U Extended Battery Module (EBM).
A Three-Year Warranty ensures that this UPS has passed our highest quality standards in design, assembly, material or workmanship and further protection is offered by a $400,000 Connected Equipment Guarantee.
-
35.20 lbs
-
Features and Benefits
Double Conversion and Pure Sine Wave Output - The OL1000RTXL2U with Online Double Conversion topology provides continuous pure sine wave output with zero transfer time by converting utility AC power to DC power and inverting it back to pure sine wave AC output. The output power is identical to or cleaner than the power from the utility company grid, free of harmonic distortion and electrical noise, resulting in optimal line clarity.
LCD Control Panel – With 43 different settings, the innovative LCD interface enables users to check UPS Status, manage UPS Setup & Control, and run Testing options. Status and Log menus provide UPS vitals including input & output voltage levels, battery information, runtime estimates, load information, event and fault logging, and other system information. The Configuration menu offer IT managers the ability to customize their OL1000RTXL2U UPS to their specific parameters of operation including output voltage, sync frequency, alarm settings and other parameters. The Test menu enables self testing to insure your UPS is operating correctly.
Removable LCD Control Panel – The LCD Control Panel on the OL1000RTXL2U can be removed and relocated for easy viewing by using a DB26 cable (sold separately) that can be attached to the front or back of the UPS. This feature provides easy access to view, up to 10 feet away, status or change settings on the UPS when its installed in a hard to reach area such as the bottom of a rack, in a crowded IT closet, or on the floor.
GreenPower UPS Eco Mode – The OL1000RTXL2U can be placed into an ECO mode that places the UPS into a bypass state with a user selectable voltage range for switching back to traditional double conversion online mode. This mode improves the UPS efficiency from 90% to 95%. Cost savings are not only achieved by reducing energy consumption, but also by lowering the heat generated by the UPS.
PowerPanel Business Edition UPS Management Software - This software suite manages the power for all servers and computers supported by the UPS on a network. Features include application/OS shutdown, event logging (power, surge, and voltage variations), hibernation mode, internal reports and analysis, as well as remote management capability for comprehensive power control.
Windows Compatibility – Our PowerPanel power management software has been fully tested and is compatible with Windows 8 32/64, Windows 7 32/64, Vista 32/64, XP 32/64, 2000, 2003, Server 2008 and Server 2012.
Linux and Virtual Machine OS Compatibility – PowerPanel power management software has been fully tested and is compatible with most mainstream brands of Linux and many of the popular versions of Virtual Machine Operating Systems such as VMware ESX / ESXi and Citrix.
Critical and Non-Critical Loads – The UPS has two banks of outlets that can be configured so that the non-critical loads shut off after a set time frame to provide additional runtime for the critical load outlet. Users can prioritize their equipments runtimes to maximize the output of the UPS to meet their power requirements.
Extended Battery Module (EBM) – The runtime of the OL1000RTXL2U can be extended by adding an EBM (BP36V60ART2U). Up to ten modules can be added and each module has its own built-in charger to ensure charge times are not impacted by additional EBMs being added. Each battery module has its own charger allowing for rapid power recovery when utility power is restored.
Smart Battery Management (SBM) – SBM uses a 3-cycle charging mode that improves battery life and reduces heat generated. The first mode charges the battery to full, the second mode maintains the charge at max, and the final mode turns the charger off and allows the battery to "rest". After a slight discharge, the UPS will restart the cycle ensuring runtimes are maintained.
Emergency Power Off (EPO) – The EPO port can be connected to a master -
# Ports: 8Communication Interface: Serial (RS-232)Communication Interface: USBConnector: Power NEMA 5-15 (F)Connector: Power NEMA 5-15 (M)
-
UPS, mounting hardware, software, cabling, documentation
-
Attributes: Double conversion onlineAttributes: RJ-11 line protectionAttributes: RJ-45 line protectionColor: BlackForm Factor: 2U Rackmount
-
3.5"h x 17"w x 16.9"d
-
Plug Type NEMA 5-15P
Cord Length 10ft
Outlets - Total 8
Outlet Type NEMA 5-15R (8)
Phone / Network Protection RJ11/RJ45 1-In / 1-Out -
Battery Run Time (max): 6minPower Capacity (VA): 1000VAPower Provided: 900WSurge Suppression: StandardVoltage Provided: 120V
-
Input
Voltage 100-125Vac
Input Voltage Range 60Vac - 69Vac for 0-60% Load, 70Vac - 79Vac for 0-70% Load, 80Vac - 89Vac for 0-80% Load, 90Vac - 95Vac for 0-90% Load, 96Vac - 150Vac for 0-100% Load
Input Frequency Range 40Hz-70Hz (auto-sensing)
Input Power Factor 0.99
Cold Start Yes
Output
VA 1,000 (1 kVA)
Watts 900
On Battery Voltage 100, 110, 115, 120, 125Vac (Configurable) ± 2%
On Battery Frequency 50/60Hz (Auto-Sensing or Configurable) ±0.25Hz
Overload Protection Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec, Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec
Rated Power Factor 0.9
Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load
Crest Factor 3:1
ECO Mode Voltage Regulation ±10%, ±15% (Configurable)
Bypass Internal Bypass (Automatic and Manual)
Transfer Time 0ms
Battery
Runtime at Half Load (min) 18
Runtime at Full Load (min) 6
Battery Type Sealed lead acid
Battery Size 12V/9AH
User Replaceable Yes
Hot Swappable Yes
Typical Recharge Time 5 Hours
Replacement Battery RB1290X3
Battery Quantity 3
Smart Battery Management (SMB) Mode Yes
Expandable Battery Module Option BP36V60ART2U -
This product is subject to our return policy. Please see our complete return policy for details.
-
53.9 lbs
-
Compliant Standards: ETLCompliant Standards: RoHS
-
39121011
-
3 Years
-
3 Years
-
Lifetime Connected Equipment Guarantee: $400,000
Description | Availability | Unit Price | ||
---|---|---|---|---|
View All Warranties |
Batch Add Products by Item #
16